7" Color touch screen, easy to operate
High accurate and long life electrode and TCO2 sensor
Programmable multi-format print-out
Reagent pack, real time monitoring of reagent residual volume
Up to 10,000 test results can be stored
RS-232 port, supporting bar code reader and USB interface
Sleep mode to reduce reagent consumption
option: Sample tray
Technical Data | |||
Specification: | Working environment | ||
Sample: | serum, plasma, whole blood and dilute urine | Temperature: | 5-40℃ |
Storage: | up to 10000 test results | Relative Humidity: | ≤80 % |
Printer: | Internal thermal printer | Atmospheric pressure: | 86~106 kPa |
lnterface: | RS232 port | Power supply: | AC220V±22V, 50Hz±1Hz |
Analysis Method: | ion selective electrode(ISE) | Power: | ≤120W |
Measuring time: | ≤30s | Dimension: | 340mm(L)*200mm(W)*380mm(H) |
Sample position: | 39 positions (including 5 emergency and 4 functional positions) | Net weight: | 6Kg |
Measure Data
ltems | Measuring Range | Resolution | Measuring Precision(CV%) |
K+ | 0.50-20.00mmol/L | 0.01mmol/L | ≤1.5% |
Na+ | 15.0—200.0mmol/L | 0.1mmol/L | ≤1.5% |
Cl- | 15.0—200.0mmol/L | 0.1mmol/L | ≤1.5% |
Ca++ | 0.10—6.00mmol/L | 0.01mmol/L | ≤2.0% |
pH | 4.00-9.00pH | 0.01pH | ≤2.0% |
Li + | 0.10-6.00mmol/L | 0.01 mmol/L | ≤3.0% |
Mg++ | 0.10-4.00mmol/L | 0.01 mmol/L | ≤3.5% |
TCO2 | 2.0-70.0mmol/L | 0.1 mmol/L | ≤3.5% |
Main Features
▲ Human-machine interactive menu; Dynamic and real-time display of sample lD.
▲ Liquid level automatic detection and alarming.Real-time diagnostic of system working status.
▲ Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.
▲ Wave theory flushing method and direct flushing pipe method to avoid block and crossed contamination.
▲ Automatic calibration and two-point correction to adjust slope and intercept; Available to print-out QC graph and QC statistical parameters.
▲ Power failure protection to avoid data losing. Supporting fuzzy query.
▲ Supporting Lls software; Upload data format is selectable; Supporting RTC Clock management.
▲ Available to power off any time, therefore reduce reagent consumption,suitable for any hospitals.
Mo del No | Configuration |
A | K Na Cl |
B | K Na Cl TCO2 AG |
C | K Na Cl iCa nCa TCa pH |
D | K Na Cl iCa nCa TCa pH TCO2 AG |
F | K Na Cl Li |
H | K Na Cl iCa nCa TCa pH Li |
I | K Na Cl iCa nCa TCa pH Li TCO2 AG |
K | K Na Cl iCa nCa TCa pH Mg |
L | K Na Cl iCa nCa TCa pH Mg TCO2 AG |
M | K Na Cl iCa nCa TCa pH Mg Li TCO2 AG |
N | K Na Cl iCa nCa TCa pH Mg |